Postnova Analytics
af2000 multiflow fff system Af2000 Multiflow Fff System, supplied by Postnova Analytics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/af2000 multiflow fff system/product/Postnova Analytics Average 86 stars, based on 1 article reviews
af2000 multiflow fff system - by Bioz Stars,
2026-05
86/100 stars
|
Buy from Supplier |
|
Waters Corporation
eclipse af4 ![]() Eclipse Af4, supplied by Waters Corporation, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/eclipse af4/product/Waters Corporation Average 96 stars, based on 1 article reviews
eclipse af4 - by Bioz Stars,
2026-05
96/100 stars
|
Buy from Supplier |
|
Postnova Analytics
mals detector ![]() Mals Detector, supplied by Postnova Analytics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/mals detector/product/Postnova Analytics Average 86 stars, based on 1 article reviews
mals detector - by Bioz Stars,
2026-05
86/100 stars
|
Buy from Supplier |
|
Postnova Analytics
af200 multiflow system ![]() Af200 Multiflow System, supplied by Postnova Analytics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/af200 multiflow system/product/Postnova Analytics Average 86 stars, based on 1 article reviews
af200 multiflow system - by Bioz Stars,
2026-05
86/100 stars
|
Buy from Supplier |
|
Waters Corporation
eclipse ![]() Eclipse, supplied by Waters Corporation, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/eclipse/product/Waters Corporation Average 97 stars, based on 1 article reviews
eclipse - by Bioz Stars,
2026-05
97/100 stars
|
Buy from Supplier |
|
Postnova Analytics
cross flow syringe pump ![]() Cross Flow Syringe Pump, supplied by Postnova Analytics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/cross flow syringe pump/product/Postnova Analytics Average 86 stars, based on 1 article reviews
cross flow syringe pump - by Bioz Stars,
2026-05
86/100 stars
|
Buy from Supplier |
|
Postnova Analytics
isocratic pumps pn1130 ![]() Isocratic Pumps Pn1130, supplied by Postnova Analytics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/isocratic pumps pn1130/product/Postnova Analytics Average 86 stars, based on 1 article reviews
isocratic pumps pn1130 - by Bioz Stars,
2026-05
86/100 stars
|
Buy from Supplier |
|
Postnova Analytics
solvent degasser pn7520 ![]() Solvent Degasser Pn7520, supplied by Postnova Analytics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/solvent degasser pn7520/product/Postnova Analytics Average 86 stars, based on 1 article reviews
solvent degasser pn7520 - by Bioz Stars,
2026-05
86/100 stars
|
Buy from Supplier |
|
Postnova Analytics
flow fff control module ![]() Flow Fff Control Module, supplied by Postnova Analytics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/flow fff control module/product/Postnova Analytics Average 86 stars, based on 1 article reviews
flow fff control module - by Bioz Stars,
2026-05
86/100 stars
|
Buy from Supplier |
|
Postnova Analytics
mals detector operating ![]() Mals Detector Operating, supplied by Postnova Analytics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/mals detector operating/product/Postnova Analytics Average 86 stars, based on 1 article reviews
mals detector operating - by Bioz Stars,
2026-05
86/100 stars
|
Buy from Supplier |
Image Search Results
Journal: Journal of Controlled Release
Article Title: Physical characterization of liposomal drug formulations using multi-detector asymmetrical-flow field flow fractionation
doi: 10.1016/j.jconrel.2020.01.049
Figure Lengend Snippet: The MD-AF4 method can help both drug developers and regulators alike to better characterize the physical properties of liposomal drug formulations. The method offers much more than simply size analysis, as highlighted in this diagram.
Article Snippet: Included were an Eclipse DualTec (Wyatt Technology), an
Techniques:
Journal: Journal of Controlled Release
Article Title: Physical characterization of liposomal drug formulations using multi-detector asymmetrical-flow field flow fractionation
doi: 10.1016/j.jconrel.2020.01.049
Figure Lengend Snippet: Top from left to right, schematic illustration of injection/focusing/relaxation step, elution with fractionation, and resulting fractogram for AF4. Bottom left to right, simplified flow diagram showing principal components of MD-AF4 instrument systems used in this study .
Article Snippet: Included were an Eclipse DualTec (Wyatt Technology), an
Techniques: Injection, Fractionation
Journal: Journal of Controlled Release
Article Title: Physical characterization of liposomal drug formulations using multi-detector asymmetrical-flow field flow fractionation
doi: 10.1016/j.jconrel.2020.01.049
Figure Lengend Snippet: Comparison of elution programs applied to Dox1. AF4 fractograms resulting from different elution programs (normalized excess Rayleigh ratio at 90°), R g (line) and the R h (dots) as a function of elution time for injection of 25 μg of Dox1. Constant XF = 0.3 (black), exponential decay from XF = 1.0 to 0 in 60 min (red) and linear decay from XF = 1.0 to 0 in 30 min (blue). (For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.)
Article Snippet: Included were an Eclipse DualTec (Wyatt Technology), an
Techniques: Comparison, Injection
Journal: Journal of Controlled Release
Article Title: Physical characterization of liposomal drug formulations using multi-detector asymmetrical-flow field flow fractionation
doi: 10.1016/j.jconrel.2020.01.049
Figure Lengend Snippet: Determination of the upper size limits using online detectors. AF4 fractograms (normalized excess Rayleigh ratio at 90°) for PSL (15–100) nm (radius) with R h at FWHM (dots) overlaid. (Top) A) MALS (Wyatt), B) online QELS and C) online Zetasizer (Malvern) measured at DF = 0.5. (Bottom) radius measured at DF = 1.0 by D) MALS, E) online QELS and F) online Zetasizer.
Article Snippet: Included were an Eclipse DualTec (Wyatt Technology), an
Techniques:
Journal: Journal of Controlled Release
Article Title: Physical characterization of liposomal drug formulations using multi-detector asymmetrical-flow field flow fractionation
doi: 10.1016/j.jconrel.2020.01.049
Figure Lengend Snippet: Optimized AF4 fractionation method for liposomal formulations.
Article Snippet: Included were an Eclipse DualTec (Wyatt Technology), an
Techniques: Fractionation, Membrane, Injection
Journal: Journal of Controlled Release
Article Title: Physical characterization of liposomal drug formulations using multi-detector asymmetrical-flow field flow fractionation
doi: 10.1016/j.jconrel.2020.01.049
Figure Lengend Snippet: Dox2: Batch DLS vs AF4 analysis using the optimized method. A) Batch DLS of Dox 2, B) Fractograms showing the elution profile of three replicate injections (normalized excess Rayleigh ratio at 90°), R g (line) and R h (dots)versus elution time after injecting 25 μg of Dox2. Blue arrows indicate identifiable component populations. (For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.)
Article Snippet: Included were an Eclipse DualTec (Wyatt Technology), an
Techniques:
Journal: Journal of Controlled Release
Article Title: Physical characterization of liposomal drug formulations using multi-detector asymmetrical-flow field flow fractionation
doi: 10.1016/j.jconrel.2020.01.049
Figure Lengend Snippet: Measurement of Dox1 and Dox2 in complex media. AF4 fractograms (normalized excess Rayleigh ratio at 90°), the R g (line) and R h (dots) versus elution time by injecting A) Dox1 and B) Dox2 with (red) and without (black) 10% FBS. Orange fractogram is the PBS + 10% FBS control. (For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.)
Article Snippet: Included were an Eclipse DualTec (Wyatt Technology), an
Techniques: Control
Journal: Journal of Controlled Release
Article Title: Physical characterization of liposomal drug formulations using multi-detector asymmetrical-flow field flow fractionation
doi: 10.1016/j.jconrel.2020.01.049
Figure Lengend Snippet: Work flow chart showing principal steps in MD-AF4 method application. Both quality control (A) and fractionation/analysis results (B) must yield green arrows to meet overall method acceptance criteria, with QC preceding sample analysis.
Article Snippet: Included were an Eclipse DualTec (Wyatt Technology), an
Techniques: Control, Fractionation